Hickok 600 800 6000 6000A tester calibration service


Submitter: florencerivas@modularparts.com (Florence Rivas)
What Florence Rivas is selling: Hickok 600 800 6000 6000A tester calibration service
We are located in, North Carolina
All service performed by Degreed Electrical Engineers with over 36 years of experience designing and servicing Tube and Solid State equipment and Tube Testers.
Service price now includes replacement of all electrolytic capacitors and replacement of all others as required.
1. Check operation of all switches and check tube sockets, clean and tighten as required
2. Check meter operation for sticking, zero set and full scale sensitivity. Adjust as required.
3. Replace all Electrolytic capacitors
4. Chek all other capacitors and replace as required.
6. Check neon bulbs and operation of short detection ciruitry
7. Check the 5Y3GT and #83 tubes
8. Calibrate all voltages according to Hickok factory calibration procedures using a high accuracy voltmeter with proper impedance
9. Calbrate and recheck the the Shunt/English dial in all three ranges 3k,6k and 15K using a custom Gm emulator ciruit and multiple 6L6 Calibration tubes. If needed, provide new red dot marker positions and/or a sticker attached to the tester with new indicator range positions.
10. Lightly clean front panel and case
11. Check the unit with a variety of good and bad power and small tubes
12. Provide a checklist and instructions on how to use the newly calbrated shunt dial.
13. Your unit will operate as accurately as it possibly can.
The calibration cost does not include the cost of any required parts replacement/labor, or labor needed to unsolder and resolder the halves of the shunt/english control to put the unit back into alignment. There is generally a $25.00 additional charge for this service. You will be notified if this is the case There will be an additional charge if parts need to replaced. Most times this is not required to get the unit to calibrate, if the unit is in working condition.
If you would like to speak to us please call at (***) 351-3781 or email us at florencerivas@modularparts.com
We also service B&K and other brands of Testers as well. Email us with your requirments.