MODULAR PARTS MODERATED NEWSGROUP and OPINIONS EXCHANGE PLACE   >   ARCHITECTURE   >   Fluke 43B power harmonics analyzer

Fluke 43B power harmonics analyzer


Submitter: LilianaGoodwin@modularparts.com (Liliana Goodwin)
What Liliana Goodwin is selling: Fluke 43B power harmonics analyzer
For all Fluke products allow 5-7 extra days. Thank You.
The Model 41B is ideal for further analyzing data and optimizing system performance. Use the Fluke 41B's FlukeView® software (included) to download acquired data to a printer or an MS-DOS® or Windows® compatible computer for analysis and presentation.
* Bargraph showing harmonic levels
Display updates three times a second for a dynamic view of actual circuit conditions.
Measure rms, peak and total harmonic distortion (THD) for complex voltages and currents - with no manual calculations required.
To make the single-phase measurement, simply connect the meter as shown and select the 3º, 3C watts display.
Immediate readings of Power Factors, KVAR, Crest Factor, K-Factor.
Display Harmonics individually to the 31st
Min/Max and Average Recording
Up to eight complete measurement sets.
Communications with a serial printer or DOS® or Windows®-compatible computer.
To meet the latest standards: IEC 1010-1, pollution degree 2, Installation Category III, material group II, 600 V. Double insulated protection as described in IEC 1010-1, Annex H.
One cycle of the fundamental waveform and its frequency. Instantaneous voltage at cursor position.
%-fundamental or %-rms, rms value, frequency, and phase angle of fundamental or harmonic currents (up to 31st), as selected by cursor from bar graph.
Watts, volt-amps, power factor (total) and displacement power factor of fundamental of single-phase or three-phase power.
Range and Resolution: 5.0 V to 600 V rms (AC+DC);
Accuracy: rms: ±(0.5 % + 2 digits); Peak or DC: ±(2 % + 3 digits) (Add 2 digits if < 15 V rms)
Range and Resolution: 1.00 A to 1000 A rms (AC+DC);
Accuracy: rms: ±(0.5% + 3 digits)+probe specs;
Peak or DC: ±(2 % + 4 digits) + probe specs
Note: AC-only 80i-500s probe included with purchase.
Range and Resolution: 0.0W(VA) to 600 kW(kVA) average;
0.0W(VA) to ±2000 kW(kVA) peak
Accuracy: AC+DC: ±(1 % + 4 digits) + probe specs
Harmonics (harmonic level >5% using Smooth 20)
Volts: Fundamental to 13th ±(2 %+2 digits);
Amps or Watts: Fundamental to 13th ±(3 % + 3 digits) + probe specs;
At 31st ±(8 % + 3 digits) + probe specs
Range & Resolution: 6.0 Hz to 99.9 Hz
Range & Resolution: 1.00 to 5.00
Range & Resolution: 0.00 to 1.00
Displacement Power Factor (DPF)
Range & Resolution: 0.00 to 1.00
Accuracy: ±0.04 to ±0.03 (0.30 to 0.89) ±0.02 (0.90 to 1.00)
Range & Resolution: -179 º to 180 º
Accuracy (Fundamental): ±2 º + probe specs
Range & Resolution: 1.0 to 30.00
Range & Resolution: 0.00 % to 799.9 %
Accuracy: ±(0.03 Reading + 2.0 %)
Range & Resolution: 0.0 % to 99.9 %
Accuracy: ±(0.03 Reading + 2.0 %)
4 alkaline "C" cells ANSI/NEDA-14A, IEC-LR14 (supplied) 48 hours typical (continuous)
Drip-Proof and Dust-Proof per IEC, IP 52
234 mm L x 100 mm W x 64 mm D (9.2" L x 3.9" W x 2.5" D)
(please look at our rules and privacy policy)
Contact LilianaGoodwin@modularparts.com (Liliana Goodwin) for more information. This email will be sent to Liliana Goodwin' actual email address.



Fluke 43B power harmonics analyzer