MODULAR PARTS MODERATED NEWSGROUP and OPINIONS EXCHANGE PLACE   >   COMPUTERS   >   Laptops   >   Old   >   Ludlum model 2221 scaler/ratemeter sca warrantied

Ludlum model 2221 scaler/ratemeter sca warrantied


Submitter: lreeves@modularparts.com (Leticia Reeves)
What Leticia Reeves is selling: Ludlum model 2221 scaler/ratemeter sca warrantied
FULL VIEW OF LUDLUM MODEL 2221 Scaler/Ratemeter SCA
LUDLUM MODEL 2221 SCALER/RATEMETER SCA
REFURBISHED AND WARRANTIED UNITS FOR SALE
CURRENT FULL-RANGE CALIBRATION AVAILABLE FOR NOMINAL PRICE TO BE QUOTED
A FRACTION OF LIST PRICE -NOW ONLY $930
A SPECIAL OPPORTUNITY TO ACQUIRE QUALITY, WARRANTIED INSTRUMENTATION IN GOOD WORKING ORDER AT BARGAIN PRICES
CERTIFIED GOOD OPERATING CONDITION are available for sale. These are fully-functional models.
Information on Ludlum 2221 and images at this moment are from Ludlum Site. Images of actual units for sale to follow.
Go to to check details of detectors listed below.
* 6 Decade LCD Scaler with backlight
* Logarithmic and Linear Ratemeter with a Total Counting Range from 0 - 500,000 cpm
COMPATIBLE DETECTORS: G-M, proportional, scintillation
CONNECTOR: Series "C" (others available)
AUDIO: Built in unimorph speaker with volume control (greater than 60 dB at 2 feet, full volume)
AUDIO DIVIDE: Thumb switch for 1, 10, or 100 events-per-click
AUDIO JACK: For optional headset
METER DIAL: 0 - 500 cpm; 50 - 500k cpm logarithmic scale (others available)
MULTIPLIERS: X1, X10, X100, X1k, and LOG for logarithmic scale
LINEARITY: Reading within plus or minus 10% of true value with detector connected
DIGITAL DISPLAY: 6 digit LCD display with 0.5" (1.3cm) digits
LCD BACKLIGHT: Activated by LAMP switch
DIGITAL RATEMETER: Provides a digital display of count rate when selector switch is in Dig. Rate position
SCALER: Used in conjunction with timer to allow for gross counting with range from 0 - 999999 counts when selector switch is in Scaler position (controlled by COUNT and HOLD buttons)
NOTE: Scaler and digital ratemeter are active when not selected, allowing for concurrent use
TIMER: Switch selectable divisions of 0.1, 0.5, 1, 2, 5, 10 minutes or CONT (continuous ) for manual timing
CALIBRATION CONTROLS: Accessible from front of instrument (protective cover provided)
HIGH VOLTAGE: Adjustable from 200 - 2400 volts (can be checked on display)
THRESHOLD: Adjustable from 100 - 1000 (can be checked on display)
WINDOW: Adjustable from 0 - 1000 above threshold setting (can be turned on or off)
GAIN: Adjustable from 1.5 - 100 mV at threshold setting of 100
OVERLOAD: Senses detector saturation. Indicated by "-" on LCD display and meter going to full scale (adjustable depending on detector selected)
RESPONSE: Toggle switch for FAST (4 seconds) or SLOW (22 seconds) from 10% to 90% of final reading
RESET: Push-button to zero meter
POWER: 4 each "D" cell batteries (housed in sealed compartment that is externally accessible)
BATTERY LIFE: Typically 250 hours with alkaline batteries (battery condition can be checked on digital display)
METER: 2.5"(6.4cm) arc, 1 mA analog type
CONSTRUCTION: Milled and drawn aluminum with beige polyurethane enamel paint
TEMPERATURE RANGE: -4° F(-20° C) to 122° F(50° C)
May be certified for operation from -40° F(-40° C) to 150° F(65° C)
SIZE: 9"(22.9cm)H X 4.3"(10.9cm)W X 10"(25cm)L including handle
WEIGHT: 5.5 lbs (2.5kg) including batteries
For Alpha/beta/gamma Measurements
Air and Water Tight Carrying Case
Ordering Info. Manual Technical Info.
MORE PHOTOS ARE AVAILABLE UPON REQUEST
THIS IS A VERSATILE, RUGGED UNIT DESIGNED FOR FIELD ANALYSIS AND USABLE WITH g-M, Proportional, and Scintillation detectors.
Call or e-mail Stewart Farber, MS Public Health
These units could be used for demanding high-sensitivity surveys at operating nuclear facilities or at decontamination and decommissioning proojects [D&D projects]. In addition these units have potential application for First Responders, homeland security, guarding borders and seaports, counter-terrorism operations, security at points of access control such as airports to detect radioactive materials or contamination, or in response to nuclear incidents.
This unit is discounted substantially from its new price and guaranteed to be in good working condition.
RADIOLOGICAL SURVEY INSTRUMENTATION
All instruments will come with a 30 day supplier warranty.
CONTACT TO CONFIRM CURRENT AVAILABILITY - INVENTORY CHANGES DAY TO DAY. ALL INSTRUMENTS SUBJECT TO PRIOR SALE AND ARE OFFERED ON A FIRST-COME, FIRST-SERVED BASIS.
Stewart Farber, MS Public Health [203] 441-8433
Most instruments on list below are from Ludlum and offered at or below one-half list price
Eberline Thermo PCM-2 Personnel Contamination Monitor
Thermo IPM-9D Personnel Contamination Monitor [include gamma option]
MODEL 177 Qty: 123 - Frisker Station Count Rate Meter
MODEL 177-45 Qty: - 5 Frisker Station Count Rate Meter
MODEL 180-2 Qty: 4 - Pancake Holder Jig for 44-9
MODEL 2200 Qty: 2 - Scaler Ratemeter Single Channel Analyzer
MODEL 2221 Qty: 207 - Count Rate Meter
MODEL 2241-1 Qty: 1 - Scaler (like 2241)
MODEL 2241-2 Qty: 9 - Count Rate Meter
MODEL 2929 Qty: 4 - Scaler Dual Channel Analyzer
MODEL 43-10-1 Qty: 4 - Dual Smear Counter Probe
MODEL 43-37 Qty: 30 - Floor Monitor Probe
MODEL 43-5 Qty: 86 - Alpha Probe
MODEL 43-68 Qty: 76 - Dual Gas Proportional Probe
MODEL 43-68/5 Qty: 10 - Dual gas Broom handle
MODEL 500-2 Qty: 1 - Pulser (calibrator)
MODEL 6A-1 Qty: 3 - Alpha Continuous Air Monitor
MODEL 6A-1RH Qty: 3 - Alpha CAM w/Remote Head
MODEL AUTO Quik 5 Qty: 3 5 Station Buck Charger for IH, HFs
MODEL D-530 Qty: 1 - Digital Hi Vol Air Sampler Calibrator
MODEL D-812 Qty: 1 - Digital Air Sampler Calibrator
MODEL DMC 2000S Qty: 8 -Alarming Dosimeter
MODEL GILAIR5 Qty: 18 -Lapel Air Sampler
MODEL HFATR-5 Qty: 7 - Gillian 5 Station Charger
MODEL HV-1ST Qty: 3 - Hi Vol Air Sampler w/Timer
Tennelec MODEL LB5100 Qty: 1 -Automatic Low Background Smear/Sample Counter
MODEL LV-1 Qty: 1 Low Volume Air Sampler MODEL LV-14M Qty: 24 - Low Volume Goose Neck Air Sampler
MODEL PAM-1 Qty: 12 - DMC2000S accessory
MODEL SKC Qty: 10 - Lapel Air Sampler
MODEL SKC CHARGER Qty: 3 - Battery Charger for SKC Lapel Air Samplers
MODEL T1031-1 Qty: 3 - Digital Gas Timer
Tennelec MODEL XLB Qty: 2 - Low Background Automatic Swipe/Sample Counter Series 5
NOTE: ALL INSTRUMENTS ARE SUBJECT TO PRIOR SALE AND ARE OFFERED ON A FIRST-COME, FIRST-SERVED BASIS.
(please look at our rules and privacy policy)
Contact lreeves@modularparts.com (Leticia Reeves) for more information. This email will be sent to Leticia Reeves' actual email address.